How to plan ahead of schedule data wiring?

2023-08-19

Data wiring is the passageway that the data with main business transmits, is a cable not just, reliable and the essential condition that quick data wiring solution is company business success.

Data cable transmits electronic information destination from data source. Current, the data cable type that is used extensively at the computer and telegraphic system basically is cupreous cable is mixed fiber-optic.

The gold law of data wiring --

Design of wiring of the existence in if the enterprise is in,be being carried out and installation are improper, will may appear a lot of problems that preview hard.

It is a few regulation that the consideration wants when system of program structuralization wiring below:

The network transmits demand to won't become smaller or simpler forever. Compose builds a wiring system that can contain speech and data. Install from beginning to end than needing more cable currently. These additional cable and interface are met sooner or later the use on the clique. Structured wiring level is used when compose builds new wiring system, can shun any proprietary stuffs effectively! Quality is very important! The wiring of use high quality and wiring component. Wiring is the foundation of the network, if wiring appears breakdown, other everything will become not matter. To giving the wiring of grade or category, will see a series of different prices, but costly case does not mean top quality certainly. Buy according to the fame of manufacturer and the property that pass test and verify, is not a consideration price. Do not want miserly installation fee. Even if high grade component and cable also must be installed correctly; What inferior construction Gong carry destroys will be more than device of a wiring. The program compares current and general practicable more high speed technology. Because net of aether of certain tall bandwidth looks today,do not have merely necessary, do not mean it to be in future needed no longer inside 5 years. Although documentation record is as dry as a chip drab, but when installing wiring system, must noticing.

Use reliable wiring from beginning to end

Can say, how do we emphasize the importance of reliable wiring be. Recent a few research make clear:

Data wiring holds network infrastructure totle drilling cost only normally less than 10% . The service life of typical wiring system can amount to 16 years of above. Cable may be the 2nd macrobian property that a lot of enterprises own (the first structure that is a building) . In all problems related to the network, near 70% because bad wiring technology and cable component problem are caused,be.

If installed the cable of correct category or grade, most wiring problem normally with jump line, connector and termination technology are concerned. The permanent link part of cable (the part on the wall) unless be in,be damaged, become an issue unlikelily otherwise.

Of course, these are our basises before the fact that experience has known. A lot of enterprises often spent many time bad to nonstandard, design, record is not complete with installation undeserved wiring system has trouble removal. We had seen a lot of charge are in to install additional wiring and wiring infrastructure by waste on support, and these one part that should attribute primitive installation.

Accordingly, no matter you how look upon, wiring is the foundation of the network.

Data wiring and speed

In a few years of in the past, obtained tremendous progress in network technology respect not only, and also obtained tremendous progress in the demand side to network technology. In 30 years of in the past, we saw 10Mb aether net, 16Mb makes card annulus, 100Mb FDDI(fiber-optic distributed data interface) , asynchronous of 100Mb aether net, 155Mb ATM(transmits mode) , the occurrence of the standard such as net of aether of net of aether of net of aether of 655Mb ATM, 1Gb, 2.5Gb ATM, 10Gb, 40Gb and 100Gb aether net. Network technology designs personnel to had been as high as 400Gbps in program support, even the technology of 800Gbps data rate.

Net paragraph the average length check the number that attend decreases quickly, and applied amount and transmission data bulk increase quickly however. Application becomes more and more complex, the network bandwidth amount that typical user place requires also is increasing. Whether to need a few new freeboard today does fast network apply (for example 10Gb aether net) offerred bandwidth? Perhaps not be a desktop, but network backbone net had used them.

Do software application process and data raise taller and taller requirement to the network what do fact of this be related and data wiring have to concern? Somebody may think this problem is more line of the ground and network interface card, collect implement, switching equipment and road by implement about, but rise along with what a move in chess or a movement in wushu occupies rate, the demand of function of higher to cable level also is increasing.

Transmit the type of medium

The communication medium that there are 4 kinds of main kinds today (cable) can use at data network:

Blame screen double skeining thread (double skeining thread of UTP) screen or screen (STP or ScTP) coaxial wire cable is fiber-optic (FO)

Cable of divisional main force and horizontal cable are very important. Server of backbone cable join, switching equipment, road by implement wait for network equipment, join computer room and telegraphic computer room. Horizontal cable from telegraphic computer room outspread the electrical outlet to the wall. To new setup, many optical fibre cable basically is general trunk cable. To transverse, 85% what UTP takes representative application market. However, the network develop with updated fiber-optic be based oning attacks to have more and more advantages than UTP.

Cable of double skeining thread

In traditional installation, current most economy and the wiring with the most extensive installation is wiring of double skeining thread. It is cheaper that double skeining thread compares other media not only, and installation is simpler also, the tool that installation requires is so not costly also. Blame screen double skeining thread (double skeining thread of UTP) and screen (STP) is two kinds of on current market main double skeining thread. Screen type double skeining thread (ScTP) is STP is aberrant.

Blame screen double skeining thread (UTP)

Although it already was in phone system,use old, but appear as what be based on the aether net of double skeining thread and 10Base-T standard, the blame screen double skeining thread that is used at LAN (UTP) becomes general first in acting 1980 later period. UTP has cost effectiveness and installation is simple, and its bandwidth ability is in rise ceaselessly.

Screen double skeining thread (STP)

Screen double skeining thread (STP) wiring is in by IBM above all the popularity when introducing data wiring type to classify rises. Although buy with UTP of installation cost prep above, but STP has a few clear advantages. Current ANSI/TIA-568-C wiring level approbates cable of level of IBM Type 1A, it supports the frequency that is as high as 300MHz, but do not suggest to use its at new setup. STP cable compares UTP cable more be disturbed not easily by exterior electromagnetism (EMI) , because all cable are right,received very good screen.

Screen type double skeining thread (ScTP-ScreenedTwistedPair)

The accepted cable type in ANSI/TIA-568-C standard is screen type double skeining thread (ScTP) cable, it is the mixture body of STP and UTP cable. ScTP cable includes 24 AWG of screen of 4 pairs of blame, 100 ohmic wire, there is foil screen all round layer or the line that pack and the platoon faze line that are used at ground connection purpose.

Accordingly, scTP also calls aluminum foil screen sometimes twinning cable (namely Foiled Twisted Pair, FTP) , because layer of aluminum foil screen surrounded 4 all conductor. Unlike of screen of this kind of foil is certain STP wiring system (for example IBM 1 with 1A model) use braid copper to braid jacket so big. ScTP cable is substantially not the STP cable that each lines are opposite screen; The STP wiring that screen compares certain type possibly also is small. In short, scTP was done between cost and interference rejection eclectic.

Full screen double skeining thread (S/STP or S/FTP)

S/STP wiring, also call full screen double skeining thread (S/FTP) , include the independent screen line of 4 pairs of 24 AWG, 100 ohm, surrounding to enclothe whole screen copper cash to be opposite all round the layer of exterior metal screen of the group. The wiring of this kind of type provided best protection, avert the interference that gets exterior source, and still was eliminated ab extra string together faze, offerred the greatest potential for higher rate thereby.

7 kinds with 7A kind the S/STP cable that is the standardization in ISO 11801 Ed2.2. Offer the 600 usable bandwidth with 1000MHz respectively. Its anticipate utility is to be used at net of 10 Gigabit aether, 10GBase-T application. The lead that S/STP cable has 4 alone screen is right.

Optical fibre cable

Till 1993, to move toward desktop calculative future, the enterprise appears to still must install optical fibre cable the desktop directly. Surprising is, cupreous cable (UTP) performance has continued at anticipating.

Single standard optical fibre cable

Cable of Chan Moguang fine most in often be being used at transcontinental link and data installation by telegraphic company, as interrelate the backbone cable of the building. Optical fibre cable need not make single standard join the computer collect line implement horizontal cable, also do not join telegraphic room via often using as advocate the cable of equipment room. The light in single standard cable is immediate along fiber-optic transmission, and be when transmission won't be reflexed by the bag layer all round. Typical single standard wavelengh is 1310 with 1550 accept rice.

Much model optical fibre cable

Much model is fiber-optic (MMF) cable is the optical fibre cable that is used at network application normally, need net of fiber-optic 10Base-FL, 100Base-F, FDDI, ATM, thousand aether, A10 for example the optical parts of an apparatus that net of thousand aether net, 40 thousand aether and net of 100 thousand aether use at level and trunk cable. The mode of a kind of above that much model cable allows light (the one part of smooth pulse) travel through cable. The typical smooth wavelengh that uses in much model cable is 850 with 1, 300 accept rice.

Coaxial cable

Once, coaxial cable is a network the most extensive cable type is used in business, coaxial cable standard already was included now in ANSI/TIA-568-C.4. It is used extensively still at closed-circuit television and other video to allocate, use extensively at broadband and cable television application. However, it is being washed out in data network domain. Coaxial cable hard laid, and compare cable of double skeining thread normally costly. However, to protect coaxial cable, it offerred tremendous bandwidth, and unlike UTP gets easily in that way exterior interference. Overall installation cost is potential also under other cable type, because the installation time of connector is shorter.

With the material that is isolated from at electrical wiring

Current, put in a variety of insulating material, include polyolefin (polyethylene and polypropylene) , carbolic fluorine polymer and PVC.

Manufacturer basis is cost of material, flame retardant the transmission character that grade and place need will choose material. The material price such as polyolefin is low and have excellent transmission performance, but they are easy burn, accordingly must will they and it is better to have flame retardant the material union of grade is used. Remember this are very important: Not dedicated at specific data. Important is the data system that manufacturer selects. Manufacturer will be mixed according to fireproof sex, transmission function socioeconomic is delicate the insulation that will choose to work in coordination evenly and jacket material.

Use at insulation 5e kind and taller flame retardant the commonnest stuff with the right string in class cable is polymer of carbolic fluorine compound. Polymer of use fluorine of two kinds of carbon is fluorine changes ethylene - propylene (FEP) and oxygen of complete fluorine alkyl base (PFA) .

These polymer are developed by Dubang at first, also name with its brand Teflon sometimes. In these material the most commonly used with optimal it is FEP. In going a few years, right flame retardant the demand of class cable exceeded what can use FEP to supply. During FEP is in short supply, appeared 5e kind pressure boost design, replace a pair with another kind of material or many pairs of electrical wiring.

In addition, in flame retardant example of function of a few brims appeared in the UL-910 combustion test of cable. These is anxious, plus the addition that the substitute such as FEP and MFA supplies, had promoted the development of these designs.

Insulation color

The insulation layer all round every electrical wiring in UTP cable is colored encode. The color code of standardization conduces to cable installing personnel to ensure every electrical wiring joins correctly with hardware. For example, be in the United States, color code is based on 10 kinds of color. Among them 5 are used on most advanced conductor, 5 are used on annular conductor. Will most advanced color and annulus color combination can produce 25 kinds of possible distinctive conjugate combination. Accordingly, come a few years, phone cable used 25 lines to be opposite group.

Twine

When telecommunication cable of your incision UTP, you can notice each conductor in a pair of electrical wiring are twined together each other. At first, you may not realize these twined value.

Whether do you know to be in 5e kind in cable, a pair not does wring exceed half-inch line to you can produce adverse effect to the function of whole cable?

Wire gauge

Copper cash diameter is used normally call AWG (American wire gauge) the unit is measured. With a lot of other survey a system contrary, as AWG number decrescent, line means greatens actually; Accordingly, AWG 24 line is smaller than AWG 22 line. Bigger electrical wiring is very useful, because they have higher physical intensity and lower resistance.

The challenge that cable stylist faces is use diameter as far as possible small electrical wiring (reduce cost and installation complexity) , the performance that at the same time utmost land improves electrical wiring is made the same score with supporting necessary power water with frequency.

5e kind UTP is 24 AWG from beginning to end; IBM Type 1A is 22 AWG normally. Jump the line may be 26 AWG, especially 3 kinds jump line. 6 kinds with 6A kind the development that waits for more high-powered cable brings about 23 AWG to often be replaced by 24 AWG.

Next watches showed 22, 23, 24 with 26 AWG dimension and corresponding diameter, area and every kilometer weight.

AWGNominal Diameter (in)Nominal Diameter (mm)Circular-Mil (cm)Area (mm2)Weight (Kg/Km)220.02530.643640.40.32562.895230.02260.574511.50.25812.295240.02010.511404.00.20471.82260.01590.404253.00.12881.145

The dimension in be being expressed on is in the 100 many development year ago. Thenceforth rises, as a result of better copper processing technique, cupreous purity and electric function got rising. The standard that covers telecommunication cable design forgoed the real measure of electrical wiring. What care truly is not the dimension of electrical wiring, however its function how, especially about resistor (it is an unit with ohm) . AWG standard shows the diameter of 24 AWG electrical wiring is 0.0201 " , but the function according to material, the actual diameter of electrical wiring is likely slightly small or slightly big (but the conference is normally smaller) .

Sincere conductor and wring add up to conductor

Use as horizontal cable (the cable inside permanent cable or wall) UTP cable has sincere conductor, this and jump the cable of line and stone's throw wiring is contrary, latter is had normally wring add up to conductor. Many lead interweaves together to form a lead by a lot of lesser lead.

Cable length

Cable is longer, as a result of noise and signal attenuation, signal is conveyed completely cable endmost possibility is less. But want to realize, to LAN system, the time that signal arrives at terminal place to need is very crucial also.

Cable designs an engineer to measuring two of cable additional performance data now: Transmit defer and defer deviation. The length with the rate that these two parameter carry cable with the electron and cable right central line is concerned.